TP23Z1: Arrester
Product code: 6563CD
- Outline
-
This equipment is arrester board of AC200V of the relay station transmission equipment. This is prevented being destroyed by the thunder.
- Structure
-
JIS rack mounting type
External size: 480(W) x 99(H) x 450(D)mm (Excluding protrusions)
Mass: 11kg or less - Specification
-
Input Arrester GL-L2F by OTOWA Electric Co., Ltd
GL-L2G by OTOWA Electric Co., LtdRating voltage 220V Maximum permissible voltage 260V Discharge Tolerated dose
(8/20μs)20kA 2times Use conditions Continuous use Environmental
requirementsTemperature -10°C to +45°C (Range for in-spec) -20°C to +60°C (Range for spec restorable) Humidity 45% to 90%RH (Without dew.) - Function
-
This equipment mounts the arrester of AC200V by two methods. The arrester is mounted between live-playground, live-neutral, and neutral-grandeur at one power supply method. The arrester uses the ZnO element with an excellent non-straight-line-resistance characteristic in which the zinc oxide etc. is assumed to be a principal ingredient. Moreover, it is a plug-in structure, and it is possible to exchange it from the front side easily. The watching check is possible from the transparent window for the check with built-in the separation device.
- Operation explanation
-
This equipment is composed of the terminal stand for the input and the terminal stand for the output. It is connected from the terminal stand for the input with each arrester, and it is connected with the terminal stand for the output. The power supply of the relay broadcasting system is protected from a thunder surge, a switching surge, and a multiple thunder. Because the arrester between grandeur is built-in the series gap, only when serge invades, it is impressed to the element. Moreover, when the element of the arrester between methods is deteriorated, the device that automatically separates the element from the circuit is built into.