This is a device used for the transmission and the reception separation station in the relay station. It separates the signal that has been sent from the reception part to analog-IF and digital-IF , and outputs it to the transmission conversion part. Besides, it sends the standard reference signal (10MHz) and AC60V power to the reception part by superposing them on the transmission line
JIS rack mount type
External size: 480(W) x 149(H) x 350(D)mm (Excluding protrusions.)
Mass: 16kg or less
Name of articles | Specifications | Amount | Remarks |
AC power cable | With 2PIN connector Length 2m | 1 | RM15QPS-2SA |
DC power connector | 4PIN | 1 | RM15QPS-4SA |
Fuse | 3.2A | 3 | SMP32-3.2A |
Input frequency | Standard reference signal: 10MHz | |
Input level | Standard reference signal: +13dBm | |
Input impedance | 50Ω | |
Input connector | BNC type FEMALE | |
Output frequency | Analog-IF: 19.5MHz ± 3MHz | |
Digital-IF: 37.15MHz ± 2.79MHz | ||
Output level | Analog-IF: 80dBμV | |
Digital-IF: -10dBm | ||
Output impedance | 50Ω | |
Output connector | BNC type FEMALE | |
Transmission line I/O impedance | 50Ω | |
Transmission line I/O connector | BNC type FEMALE | |
Transmission line | 5D-2W (Transmission line loss maximum value) | |
Transmission line length | 800m Target (It changes depending on the type, length, and the passing current of the transmission line.) | |
AC superposed power supply | AC60V 1.5A or less | |
Power supply voltage | AC: 100V ± 15% or less 50/60Hz | |
DC: 48V(36 to 72V) | ||
Power consumption | AC: 120VA or less | |
DC: 150W or less | ||
Use conditions | Continuous use | |
Environmental requirements | Temperature | -10°C to +45°C (Range for in-spec) |
-20°C to +60°C (Range for spec restorable) | ||
Humidity | 45% to 90%RH (Without dew.) |
Frequency characteristics | 0.4dBp-p or less In pass band |
Input return loss | 18dB or more |
Gain | Analog-IF: 8dB or more |
Digital-IF: 33dB or more | |
Standard oscillation: 4dB or more | |
NF | 12dB or less |
Inter-modulation (synthesis of transmission and reception) |
Analog-IF: Input level of reception+7dB, At the maximum tilt -55dB or less |
Digital-IF: Input level of reception+7dB, At the maximum tilt -50dB or less | |
Output level changeable amount | ±5dB or more |
Tilt changeable amount | 7dB or more( The tilt function is not provided for a standard oscillation.) |
Isolation | 30dB or more |
Surge protection amount | DC 800V, Impulse 1000V |
(Surge arrester made by EPCOS company. From the parts catalog A71-H08 ) |