PM2M2A: Multi-channel power meter
Product code: 5639DC
It was developed in conjunction with NIPPON ELECTRONIC SYSTEMS CO., LTD.
- Outline
-
This is power meter with automatic monitor function to measure and to observe RF level of each channel of MCPA (Multi Channel Power Amp) used by Digital Terrestrial Broadcasting. The RF signal of 4 waves or less is input, and the RF level of each channel is measured by timesharing. The measured power level percent display of rated power as 100% with an analog meter. As alarm function, when the measured level exceeds the pre-set threshold, the point of contact is output outside and alarm indication is displayed.
- Structure
-
JIS rack mounting type
External size: 480(W) x 49(H) x 350(D)mm (Excluding protrusions)
Mass: 3.5kg or less - Specification
-
RF Input Frequency 473 to 767 MHz (13 to 62 ch) Number 1 method Number of measuring cannel Max. 4 wave Power level -20 to +5 dBm or less(adjusted by ATT.) Impedance 50Ω/TNC connector Alarm output RF power level
Abnormal alarm
(Point Make, when abnormal)Contact
outputNon-voltage contact output(Photo-Moth relay) Contact rating DC50V 400mA (Register load) Output connector D-sub 37 pin (S), M2.6 screw type Power supply alarm Power
failure
alarmNon-voltage contact output is done, in the case of power supply abnormal such as power SW off, power supply stop by circuit abnormal, AC input off, and etc.(Contact is Make, when abnormal) Alarm output Setting final time
(Setting time is All channel
commonness)Time from 0 to 5 minutes can be set every second. RF power level abnormal alarm setting (The rated power is assumed to be 100 %.) RF power level upper bound alarm setting. (Setting is All channel commonness) RF power level decrease caution alarm setting. (Setting is All channel commonness) RF electric power level lower bound alarm setting. (Setting is All channel commonness) Meter output DC out put DC 3V output at rating output (100%) Output connector D-sub 25pin (S), M2.6 screw type Telemeter output DC out put DC 3V output at rating output (100%) Output connector D-sub 25pin (S), M2.6 screw type Communication LAN (RS-232C is optional, and using with LAN together is improper.) Interface IEEE 802.3 10BASE/T Protocol TCP/IP Connector Modular jack RJ45 General specification Power supply voltage DC+48V ±15% ( [DC IN-1], [DC IN-2] 2 methods input) Power consumption 20W or less Use conditions Continuous use Environmental
requirementsTemperature -10°C to +45°C (Range for in-spec) -20°C to +60°C (Range for spec restorable) Humidity 45% to 90%RH (Without dew.) - Performance
-
Measuring range Range of 150% fro 10%, when the ratings input as 100%. Input power level
measurement accuracy±0.5dB of rating input (Range of 150% fro 50%) ±1dB of rating input (Range of 50% fro 10%)
Attention: The power measurement only in the career cannot be done in the principle of the measuring method.