MP2MA0: Meter panel
Product code: 6556A
- Outline
-
This is the meter panel for the relay station of Digital Terrestrial Broadcasting. The input corresponds to a single channel.
In addition to the display of transmitting power, the output levels, the power-supply voltage, and FET current of the power amplifier in two methods is displayed. - Structure
-
JIS rack mounting type
External size: 480(W) x 99(H) x 450(D)mm (Excluding protrusions)
Mass: 4.5kg or less - Specification
-
(Input level is a mean value.)
Input frequency Specified UHF channel (single channel) Input level -30dB against Specified PA output level Input impedance 50Ω/TNC type (Unbalance) Display (selected by SW) Ratings transmitting power(%), The output levels, the power-supply voltage, and FET current input from PA1 and PA2 are displayed by (%), (V) or (A).(Meter full scale 300mV/1.5kΩ) Power supply voltage DC+48V±15% or less (when input at two methods) Power consumption 3W or less Environmental
requirementsTemperature -10°C to +45°C (Range for in-spec) -20°C to +60°C (Range for spec restorable) Humidity 45% to 90%RH (Without dew.) Use conditions Continuous use - Performance
-
Transmitting power failure (ALARM) Red LED lights when It decreases to the ratings transmitting power by 3dB, and abnormality is output by the point of contact. Transmitting power abnormal (Alert) It is possible to add it by the option. Detected Output +5V is output at the ratings transmitting power. Interface Transmitting power
detectionNon-voltage contact outputContact rating DC24V, 0.1A or less (ALARM)DC voltage (detected output) D-sub 15S M2.6 type PA display
(PA DET1, PA DET2)DC voltage (PA output, PA power supply voltage, PA FET current) D-sub 9P M2.6 type - Function
-
This equipment displays the meter of transmitting power, and can input each meter output of the output level, the input power-supply voltage, and the FET current from SCPA up to two methods or less at the relay station adapting SCPA of Digital Terrestrial Broadcasting. By selecting with meter switch on the panel, of each is displayed in the meter.
About transmitting power display, because it has the circuit internally, the level can be observed by inputting the signal from the monitor output of the output filter, the branch output of SCPA and etc. to this equipment.
When It decreases to the ratings transmitting power by 3dB, Red LED lights , and abnormality is output by the point of contact. It is also possible to mount another one method of abnormal transmitting power (option), and to use it as a caution output of the level decrease.