This is a device that delayed OFDM modulation IF signal at the arbitrary set time. By using this at the relay station, OFDM modulation waves that passed different transmission route becomes possible to output by arranging delay time. Because it is possible to operate in the front side, this is excellent in maintenance. Through/delay can be switched with a front panel and a remote control is possible by the option.
JIS rack mounting type
External size: 480(W) x 49(H) x 450(D)mm (Excluding protrusions )
Mass: 10kg or less
Name of articles | Standard | Amount | Remarks |
Power plug | 2 pin | 2 | RM15QPS-2SA |
D-sub connector | D-sub 9pin | 2 | DE-9PF-N |
Plastic case | M2.6mm screw short screw type |
2 | The above-mentioned accessory |
Signal input (IF IN) | Center frequency | 37.15MHz | |
Band width | 6MHz | ||
Range of input level | -10dBm±2dB | ||
Connector | BNC | ||
Impedance | 50Ω | ||
Number of input | 1port | ||
Signal output |
IF OUT | Center frequency | 37.15MHz |
Band width | 6MHz | ||
Range of output level | -10dBm | ||
Connector | BNC | ||
Impedance | 50Ω | ||
Number of output | 1port | ||
IF MON | Center frequency | 37.15MHz | |
Band width | 6MHz | ||
Range of output level | -20dB(IF OUT relative value) | ||
Connector | BNC | ||
Impedance | 50Ω | ||
Number of output | 1port | ||
Alarm output | Number of connector | 1 | |
Connector | D-sub 9 pin(S) M2.6 mm screw | ||
Electrical interface | Non-voltage contact output Contact rating DC30V, 700mA |
||
Alarm output | Output abnormal, Power failure, Device abnormal, FAN abnormal, SW alert | ||
Control output | Number of connector | 1 | |
Connector | D-Sub 25 pin(S) M2.6 mm screw | ||
Electrical interface | Non-voltage contact output Contact rating DC30V, 700mA |
||
Delay time | BCD Output | ||
Control input | Number of connector | 1 | |
Connector | D-Sub 25 pin(S) M2.6 mm screw | ||
Electrical interface | Photo coupler input, input rating DC5V, 10mA | ||
Delay time | BCD input | ||
Power supply | Voltage | DC+48V±15% or less | |
Connector | RM15QRD-2PA | ||
Circuit breaker | 2A (Time delay type) | ||
Power consumption | 50W or less | ||
Environmental requirements |
Temperature | -10°C to +45°C (Range for in-spec) | |
-20°C to +60°C (Range for spec restorable) | |||
Humidity | 45% to 90%RH (Without dew.) |
IF output level change | -10dBm±0.5dB or less |
Frequency characteristic | 0.5dBp-p or less at the range 37.15MHz±2.8MHz |
IM | -55dB or less |
Phase noise | -56dBc or less (10Hz to 1MHz Integration value) |
Input and output return loss | 18dB or more at the range 37.15MHz±2.8MHz |
Setting delay time range | 0 to 99.9999ms Set resolution: 100ns Fixed delay time: 10 s or less |
Remote function (Option)
Through function (The input and the output are made through directly.)